Key takeaways
- Five dual fuel portable generators that run on gasoline or propane, compared on running watts for each fuel, run time, outlets, starting and noise figures.
As an Amazon Associate I earn from qualifying purchases. This post may contain affiliate links at no extra cost to you.
A dual fuel generator answers the two problems that show up in every long outage. Gasoline gives the highest output but goes stale in storage and disappears from pumps when a storm empties a region. Propane stores indefinitely in a sealed tank, runs cleaner through the carburetor, and is often still available when gas stations are closed, at the cost of roughly ten percent of the output. The best gas and propane portable generators let you choose between those fuels on the day, and the five models here cover the useful range from a mid-size essentials machine to a 10,500-watt unit that can carry a well pump and a central air conditioner through a transfer switch.
Every figure in this article comes from a maker manual, a maker specification sheet or a retailer specification page opened during research. Output is always stated separately for gasoline and propane, because a generator that makes 10,500 running watts on gasoline makes less on propane, and sizing a purchase on the gasoline number alone is how a transfer switch ends up overloaded on the fuel you actually stored.
The group is deliberately varied. There is a tri-fuel model that adds natural gas, a remote-start model for convenience, a mid-size model that can switch fuels while running, and a value model with an RV outlet. All five are open-frame, non-inverter machines with 120/240-volt output, which is the configuration that feeds a home inlet box.
Quick verdict
The DuroMax XP13000EH is the output leader at 10,500 running watts on gasoline and 10,000 on propane, with a 50-amp outlet sized for a whole-house inlet. The Westinghouse WGen9500DF is the convenience pick, adding key-fob remote start to 9,500 running watts. The Champion 100416 is the flexibility pick: it runs on gasoline, propane or natural gas from a home line. The Pulsar PG7750BCO is the balanced mid-size choice with switch-while-running fuel changeover, and the Sportsman GEN7500DF-SS is the compact essentials machine with an RV outlet for smaller panels and trailers.
Comparison table
| Product | Key spec | Best for |
|---|---|---|
| DuroMax XP13000EH | 10,500 W running on gas, 10,000 W on propane | Whole-house backup through a 50A inlet |
| Westinghouse WGen9500DF | 9,500 W running on gas, remote start | Large loads with push-button convenience |
| Champion 100416 | Tri-fuel, 8,000 W running on gas | Homes with a natural gas line |
| Pulsar PG7750BCO | 6,250 W running on gas, Switch & Go fuel change | Essentials plus a 240V circuit or two |
| Sportsman GEN7500DF-SS | 6,000 W running on gas, RV outlet TT-30R | Smaller panels, cabins and RV duty |
How we chose
The gate for this list was true dual fuel operation from the factory: a gasoline tank plus a propane inlet with a regulator hose, not an aftermarket conversion. Each model then had to publish separate running and starting watts for both fuels in its manual or specification sheet, because that pair of numbers is what a buyer sizes against a load list. Models whose makers did not state a propane output were left out.
Beyond output, we compared run time at half load on each fuel, the outlet panel (a 50-amp 14-50R or a 30-amp L14-30R decides which inlet box the generator can feed), starting systems, carbon monoxide shutoff equipment, and the noise figure the maker publishes. Weight mattered last: all five are wheel-kit machines over 175 lb, so they live in a garage corner rather than travel in a trunk.
A final screen was documentation quality. Each maker here publishes a full manual or specification sheet with the dual-fuel outputs printed separately, which is why the figures in this article can be quoted fuel by fuel. Models whose dual-fuel output existed only in retailer headlines, with no maker document behind it, were left out even when the headline numbers looked competitive.
The picks in detail
DuroMax XP13000EH
- Gasoline output: 13,000 starting watts, 10,500 running watts
- Propane output: 12,500 starting watts, 10,000 running watts (maker specification page)
- Engine: 500 cc DuroMax OHV four-stroke
- Run time: 8 hours at 50 percent load on gasoline; 6 hours at 50 percent load on propane
- Outlets: includes a transfer-switch-ready 50-amp outlet and GFCI household outlets
- Starting: push-button electric start; weight 234 lb
The XP13000EH is the largest machine in this roundup and the one aimed squarely at whole-house duty. DuroMax lists 10,500 running watts on gasoline and an unusually small derate on propane, 10,000 running watts, which means a load plan drawn up for gasoline nearly survives the switch to a propane tank. The front-facing fuel selector changes sources at the panel, and the maker lists a carbon monoxide sensor with automatic shutdown among its safety equipment.
An 8.3-gallon class tank and an eight-hour half-load gasoline run time mean one fill covers a work shift or a night. At 234 lb on never-flat tires with a folding handle, it is a roll-it-out machine, not a lift-it machine, and it should be stored where it will be used.
Pros:
- Highest running watts here on both fuels
- Small output drop when switching to propane
- 50-amp outlet matches whole-house inlet boxes
Cons:
- Heaviest model in the group at 234 lb
- Open-frame noise level typical of the class
Westinghouse WGen9500DF
- Gasoline output: 12,500 peak watts, 9,500 running watts
- Propane output: 11,200 peak watts, 8,500 running watts
- Engine: 457 cc Westinghouse OHV four-stroke, cast-iron sleeve
- Fuel capacity: 6.6 gal; run time up to 12 hours at 25 percent load on gasoline
- Outlets: two GFCI 120V duplexes, L14-30R transfer-switch outlet, 14-50R 50-amp outlet
- Starting: recoil, push-button electric and key-fob remote
The WGen9500DF's manual is one of the most complete in the class, and it supports a strong specification: 9,500 running watts on gasoline, 8,500 on propane, and three ways to start the machine, including a remote key fob that lets you start it from inside the house during a storm. The panel carries both a 30-amp locking outlet and a 50-amp outlet, so the same generator can feed a smaller inlet today and a larger one after a panel upgrade.
Westinghouse lists total harmonic distortion at or under 23 percent in the manual, which is ordinary open-frame power: fine for motors, pumps, heaters and chargers, and a reason to keep sensitive electronics on a surge protector or choose an inverter model instead. The 6.6-gallon tank and a VFT meter showing volts, frequency and hours round out a well-documented package.
Pros:
- Remote start included, rare at this size
- Both 30-amp and 50-amp outlets on the panel
- Fully documented specifications in the manual
Cons:
- High THD output, like most open-frame models
- Propane run time of about 7 hours at half load
Champion 100416
- Gasoline output: 10,000 starting watts, 8,000 running watts
- Propane output: 9,000 starting watts, 7,200 running watts
- Natural gas output: 8,750 starting watts, 7,000 running watts
- Engine: 459 cc Champion OHV; electric start with battery included
- Run time: 12.5 hours at 50 percent load on gasoline; 5 hours at 50 percent load on a 20 lb propane tank
- Safety: CO Shield carbon monoxide auto-shutoff; noise 74 dBA at 23 feet
The 100416 is the flexibility outlier: Champion builds it to run on gasoline, propane or natural gas, selected with an EZ Start dial. A 25-foot natural gas hose kit and a 6-foot propane hose with regulator are in the box, so a home with a gas line gains an effectively unlimited fuel supply at 7,000 running watts, while the 8.5-gallon gasoline tank covers the highest-output mode.
Output steps down with each fuel, which is the honest trade of tri-fuel design, and the panel reflects the intended home-backup role: a 120/240V 30-amp locking outlet and four GFCI household outlets. Champion publishes a noise figure of 74 dBA from 23 feet and covers the unit with a three-year limited warranty.
Pros:
- Runs on three fuels, including a home gas line
- Long 12.5-hour gasoline run time at half load
- CO Shield auto-shutoff fitted as standard
Cons:
- No 50-amp outlet for the largest inlet boxes
- Five hours on a 20 lb propane tank at half load
Pulsar PG7750BCO
- Gasoline output: 7,750 peak watts, 6,250 running watts
- Propane output: 7,500 peak watts, 6,000 running watts
- Engine: 420 cc Ducar OHV four-stroke
- Fuel capacity: 6.6 gal; run time 9.5 hours at 50 percent load on gasoline
- Outlets: four 120V outlets, L5-30R and L14-30R twist-lock outlets, 12V DC
- Features: Switch & Go fuel changeover while running, CO Sentry, digital meter
The PG7750BCO is the mid-size sweet spot for a house that needs essentials plus one or two 240-volt circuits. Pulsar's Switch & Go system is the headline: the generator changes between gasoline and propane while it is running, so an emptying propane tank does not mean a shutdown and a restart in the dark. A digital meter tracks voltage, frequency, run time and total hours for maintenance.
The specification sheet lists CARB and EPA approval, 12-inch never-flat wheels with folding handles, and a weight of about 177 lb, the lightest in this group by a clear margin. Output of 6,250 running watts covers refrigeration, a furnace blower, lighting, a microwave and a sump pump with room to rotate loads.
Pros:
- Switches fuel while running, no shutdown needed
- Lightest model here at about 177 lb
- CARB and EPA approved for all 50 states
Cons:
- No 50-amp outlet; 30-amp locking is the ceiling
- Two-year warranty listed by spec databases, shorter than rivals
Sportsman GEN7500DF-SS
- Gasoline output: 7,500 surge watts, 6,000 running watts
- Propane output: 6,700 peak watts, 5,400 running watts (maker notes output may drop about 10 percent on propane)
- Engine: 420 cc OHV four-stroke, 15 hp class
- Fuel capacity: 6.2 gal; run time 9 hours at 50 percent load on gasoline, 5 hours on propane
- Outlets: four 120V GFCI outlets, 120/240V outlet, 120V RV outlet (TT-30R), 12V DC
- Starting: electric and recoil; battery not included
The GEN7500DF-SS is the compact member of the Sportsman series and the only model here with a dedicated RV outlet, which makes it a natural fit for a trailer kept at home or a cabin panel. Buffalo Tools' specification sheet lists automatic voltage regulation, low-oil shutdown and a mobility kit in the box, with a run time of nine hours at half load on gasoline from the 6.2-gallon tank.
Two ownership details stand out. The electric start battery is not included, so budget for a 12-volt battery at purchase, and the propane figures follow the maker's guidance that output may be reduced by about ten percent on LPG. In return you get the smallest footprint in the group and a straightforward, well-documented machine.
Pros:
- RV outlet TT-30R fitted as standard
- Compact frame with mobility kit included
- Maker publishes a full specification sheet
Cons:
- Starter battery sold separately
- Loudest class figure here at under 80 dB per the maker sheet
Buying guide
Size on propane, not gasoline. Write the load list you truly need during an outage, add the starting watts of the largest motor on it, and compare that total with the propane running watts, because propane is the fuel most owners store long-term. If the numbers only work on gasoline, either step up a size or accept a rotation plan for the biggest loads.
Match the outlet to the inlet. A generator with a 50-amp 14-50R outlet can feed a 50-amp inlet box at full capacity; a 30-amp L14-30R caps the house load at 7,200 watts no matter how large the generator is. Extension-cord use favors more GFCI household outlets; transfer-switch use favors the locking outlets. Decide the connection method before choosing the model.
Think about fuel logistics. Propane tanks store for years and swap in seconds, but a 20 lb tank holds roughly five hours at half load for the larger machines here, so serious propane runtime means a 40 lb or 100 lb tank and a longer hose. Gasoline needs stabilizer and rotation. A natural gas connection, where the Champion 100416 can use it, removes storage from the problem entirely at a lower output.
Finally, plan placement and noise. Open-frame dual fuel generators publish figures around 74 to 80 dBA, so they belong on a pad away from bedroom windows, run outdoors only, and positioned so the carbon monoxide shutoff is a backup rather than the plan. Check for CO shutoff equipment on the specification sheet, and confirm CARB compliance if you live in California.
Propane changes the storage math more than the running math. A tank of propane keeps for years, never gums a carburetor, and can be exchanged in minutes during an outage, which is why dual-fuel owners often run gasoline for weekly exercises and keep propane as the deep reserve. The trade is output: every dual-fuel model here makes somewhat less power on propane than on gasoline, and runtime per fill is shorter on a standard tank. Tri-fuel adds the natural gas option, which never needs refilling at all where a home line exists, at the cost of the lowest output of the three fuels and a professional hookup.
Connection hardware deserves its own line in the budget. A portable this size usually feeds the house through an inlet box and an interlock kit or transfer switch installed by an electrician, and the 50-amp outlet on the DuroMax and Westinghouse exists exactly for that run. Wheel kits, covers and a heavy-gauge cord are the other real costs; all five machines here include wheels or a wheel kit per their makers, which is not universal in this class.
FAQ
How much power do I lose running a dual fuel generator on propane?
Across this group the drop runs from about five percent on the DuroMax XP13000EH to roughly ten percent on the Sportsman and Pulsar models. Makers publish both figures, so compare the propane running watts with your load list rather than applying a rule of thumb.
Can a dual fuel generator run a whole house?
The largest models here can carry most of a house through a transfer switch: the XP13000EH delivers 10,500 running watts on gasoline with a 50-amp outlet. Whole-house in practice means everything except perhaps electric resistance heat or a large electric range, and a load-management plan still helps during motor starts.
Which fuel is better for storage, gasoline or propane?
Propane. It does not degrade in a sealed tank, and it leaves no varnish in a carburetor during months of storage. Gasoline should be stabilized and rotated. Many owners run the generator on propane for storage season and keep gasoline as the high-output option for forecast storms.
Are dual fuel generators safe for electronics?
These five are conventional open-frame machines, and the Westinghouse manual lists total harmonic distortion at or under 23 percent, which is typical of the class. Motors, pumps and heaters are fine; for computers and modern electronics, many owners use a surge protector or pick a dual fuel inverter model instead, accepting lower output.
Can I switch fuels while the generator is running?
On the Pulsar PG7750BCO, yes: its Switch & Go system is built for changeover under load. On most other models the correct procedure is to shut down, move the fuel selector, connect the other supply and restart. Follow the manual for your model rather than improvising.
How long does a standard propane tank run one of these generators?
On the maker figures for this class, a standard 20 lb tank gives roughly five to six hours at half load: the DuroMax lists six hours on propane, and the Champion and Sportsman list about five hours on a 20 lb tank. Larger stationary tanks extend that proportionally, which is why dual-fuel owners who run long outages often keep a 40 lb or 100 lb tank beside the machine.
Do dual-fuel generators need different maintenance on propane?
The engine oil schedule is the same, and propane burns cleaner, so plugs and oil typically stay cleaner for longer. The fuel system is where the difference lies: gasoline left sitting is the main cause of hard starting, and running the machine on propane for its monthly exercise avoids storing gasoline in the carburetor at all. Follow the maker's exercise and storage instructions for the fuel you use most.
What size generator runs a well pump and a furnace together?
That pairing is the classic sizing test, and it is why the 9,000 to 10,500 running watt class dominates this roundup. A typical well pump and a gas furnace blower together draw a working load that the Westinghouse, Champion and DuroMax handle with headroom for lights and refrigeration, while the 6,000-watt class machines run them only with careful load management. An electrician measuring your actual loads gives the definitive answer for your house, and the answer decides which row of the comparison table you should be shopping.
Storage is the last ownership habit worth setting on day one: run the carburetor dry or keep the tank treated for gasoline storage, exercise the machine under load monthly as the makers direct, and keep the propane side capped and clean. A dual-fuel generator that starts on the first attempt in February is simply one that was stored and exercised correctly since October.
Conclusion
Dual fuel ownership is about options on the worst day of the year. The DuroMax XP13000EH brings the most power on either fuel, the Westinghouse WGen9500DF adds remote start and a complete outlet panel, and the Champion 100416 goes one fuel further with natural gas. The Pulsar PG7750BCO balances size, weight and a switch-while-running fuel system, while the Sportsman GEN7500DF-SS keeps the essentials covered with an RV outlet in a compact frame. Size your choice on propane watts and the inlet you own, and the generator will be ready on whichever fuel is in the garage.
Write Your Review
No reviews yet. Be the first to share your experience!